UNDERGROUND
STORAGE TANK SURVEY
Recently
a consulting company asked to employ our
services at a site in downtown
Los
Angeles
to
conduct a geophysical evaluation for the presence
of underground storage tanks. Historically, the
site was used as an auto repair facility.
It is our
understanding that Sanborn Fire Insurance Maps
indicated
the former location
of a UST on the southern portion of
the facility. The client indicated that
a geophysical survey was conducted previously,
but that no useful data was acquired. It
was suspected that the UST was removed,
however, confirmation
was needed to focus sampling plans and to get
closure on the site.
GPR
traverses conducted over the site
indicated one excavation
area near the end of a cut off pipe
(possibly a former vent or product line).
In addition to radar records indicating a
possible excavation, a low conductivity
response was detected with
the *M-scope (indicating a less
conductive backfill) and an asphalt
patch with slight subsidence and cracking
was noted encompassing the same area.