FORMER
UNDERGROUND STORAGE TANK EXCAVATION SURVEY
Recently a consulting
company asked to employ our services at a
site in Carson, California to conduct a
geophysical evaluation for the presence of
an excavation associated with the removal of
several underground storage tanks. Historical
records indicated that several USTs were removed
from one large excavation in the asphalt parking
lot at the southeast corner of the facility. The
exact location of the former tank pit was not
known.
GPR traverses were
conducted approximately every .5 meter on a 20
by 22 meter grid over the site. Data cross
sections and time slices were successful in
illustrating two possible product lines
extending away from the building and terminating
at a large excavation (note also the water line
trench extending across the excavation).
In addition to radar records indicating a
possible excavation, a low conductivity response was
detected with the *M-Scope (indicating a less
conductive backfill).